Can't write int8 image
Mantis Issue 479, reported by cvalladeau, assigned to cvalladeau, created: 2012-01-16
inut8 image or vector image are wrtitten as unit8 one.
1326725228 - C ValladeauFA test added here : http://hg.orfeo-toolbox.org/OTB/rev/81d698600afe.
Can come form the writing or the reading part... No problem if we write in bsq.
1326728216 - C ValladeauThe "problem" come form GDal that doesn't defines GDT_Byte but not GDT_UByte. The data is well write but the readinf cast char into unsigned char. We can't do anything there.
In the new application, we can supress the int8 write?
1326796291 - julienmI also think it's better to stick to GDAL mapping, even though we could eventually make a driver supporting int8
1326799296 - C ValladeauDone here : http://hg.orfeo-toolbox.org/OTB/rev/c6ab5e66a4fd