SARAddBandInterferogram
Replace an amplitude for input interferogram.
Description
Replace an amplitude for input interferogram and merge it to rebuild three bands (amp, pha and coh).
Parameters
Input Interferogram with correct amplitude -ininterfamp image
Mandatory
Input Interferogram with correct amplitude.
Input Compensated complex image -incomplexamp image
Mandatory
Input Compensated complex image.
Input Interferogram -ininterf image
Mandatory
Input Interferogram.
Averaging on distance for output interferogram -mlran int
Default value: 1
Averaging on distance for output interferogram.
Averaging on azimut for output interferogram -mlazi int
Default value: 1
Averaging on azimut for output interferogram.
Gain to apply on output amplitude -gain float
Default value: 0.1
Gain to apply on output amplitude
Output interferogram (after filtering) -out image [dtype]
Mandatory
Output Image : Interferogram after filtering with 3 corrected bands (amp, pha, coh).
Available RAM (MB) -ram int
Default value: 256
Available memory for processing (in MB).
Examples
From the command-line:
otbcli_SARAddBandInterferogram -ininterfamp interferogram_amp.tiff -ininterf interferogram_phacoh.tiff -out outInterferogram.tiff
From Python:
import otbApplication
app = otbApplication.Registry.CreateApplication("SARAddBandInterferogram")
app.SetParameterString("ininterfamp", "interferogram_amp.tiff")
app.SetParameterString("ininterf", "interferogram_phacoh.tiff")
app.SetParameterString("out", "outInterferogram.tiff")
app.ExecuteAndWriteOutput()
Limitations
Only Sentinel 1 (IW and StripMap mode) and Cosmo products are supported for now.