Unable to apply radiometric calibration to S1A SLC product
Mantis Issue 1321, reported by mgrizonnet, assigned to rkanavath, created: 2016-12-16
Issue in metadata parsing of Sentinel-1 SLC product:
Application.logger (FATAL) The following error occurred during application execution : /home/grizonnetm/projets/otb/src/OTB/Modules/Adapters/OSSIMAdapters/src/otbImageKeywordlist.cxx:102: itk::ERROR: Keywordlist has no output with key support_data.number_lines
Note that it works for detected product.
I don't know in which version this regression was introduced.
The related test of the SARCalibration application bypassed the issue as it does not read metadata from a S1A product but through a external geom file...
see apTvRaSarRadiometricCalibration_SENTINEL1
Able to reproduce the issue with linux 5.8 standalone binary and develop branch
Reported on otb-users:
https://groups.google.com/forum/#!topic/otb-users/lso7Sneb5BU
1483976394 - rashadkmdid you have same error with S1A SLC IW products?
for S1 test data on largeinput, I cannot reproduce error with full dataset.
I will try with an SLC IW product type
1484042715 - grizonnetmyes I reproduced the issue with a SLC IW product.
The product ID is S1A_IW_SLC__1SDV_20161012T061656_20161012T061723_013453_0157F1_2761.SAFE
1484053536 - rashadkmi had pushed a fix here. https://git.orfeo-toolbox.org/otb.git/commitdiff/cfb3ed729e5af121847a255fe022364fc1ef5ce6
but otb-data also needs an update
1484058502 - rashadkmadd a new test which reads full S1A product in mantis-1321 branch.
I also pushed this branch to testing. will see how it goes on dashboard tomorrow.