Can't open CosmoSkymed data
Mantis Issue 432, reported by cvalladeau, assigned to mgrizonnet, created: 2011-11-23
Trying to open a CosmoSkymed generates segfault on several plateform : http://dash.orfeo-toolbox.org/testSummary.php?project=3&name=ioTuGDALImageIOCanRead_COSMOSKYMED&date=2011-11-23
On Dora (which doesn't segfault), if you open the same image (LargeInput/COSMOSKYMED/Toulouse_spotlight/CSKS3_GTC_B_S2_08_HH_RD_SF_20110418180325_20110418180332.h5 or other) (not the QLK...) which size is Nx*Ny, the browser shows that the image has Nx bands... The problem can be due to the fact that this data in complex.
1322070755 - julienmFor Toulouse Spotlight dir:
Dataset CSKS2_GTC_B_S2_08_HH_RD_SF_20110417180326_20110417180333.h5 Subdatasets: SUBDATASET_1_NAME=HDF5:"/media/otbnas/otb/OTB-LargeInput/COSMOSKYMED/Toulouse_spotlight/CSKS2_GTC_B_S2_08_HH_RD_SF_20110417180326_20110417180333.h5"://GIM SUBDATASET_1_DESC=[24955x25800] //GIM (16-bit integer) SUBDATASET_2_NAME=HDF5:"/media/otbnas/otb/OTB-LargeInput/COSMOSKYMED/Toulouse_spotlight/CSKS2_GTC_B_S2_08_HH_RD_SF_20110417180326_20110417180333.h5"://S01/QLK SUBDATASET_2_DESC=[1247x1290] //S01/QLK (8-bit unsigned character) SUBDATASET_3_NAME=HDF5:"/media/otbnas/otb/OTB-LargeInput/COSMOSKYMED/Toulouse_spotlight/CSKS2_GTC_B_S2_08_HH_RD_SF_20110417180326_20110417180333.h5"://S01/SBI SUBDATASET_3_DESC=[24955x25800] //S01/SBI (16-bit unsigned integer) They all are real images so they open OK.
CSKS3_GTC_B_S_S2_08_HH_RD_SF_201102_08_HH_RD_SF_20110418180325_20110418180332.h5 SUBDATASET_1_NAME=HDF5:"/media/otbnas/otb/OTB-LargeInput/COSMOSKYMED/Toulouse