OpticalCalibration application does not save metadata information
Mantis Issue 967, reported by mgrizonnet, assigned to mgrizonnet, created: 2014-08-29
There is no .geom attached to the toa or toc file as output of the OpticalCalibration application.
I did not investigate which filters is guilty in the pipeline.
1409329023 - gpaseroI have checked on nightly builds, the TOA/TOC OpticalCalibration tests produce a geom file, except for the cases with an unknown sensor.
Is the issue specific to this "unknown sensor" case ? Is it a test case different from CTest tests ?
1409562511 - grizonnetmI confirm the bug on my side with OpticalCalibration tests (wb,phr, unknown sensor...).
I think that the bug is specific to OTB configuration with external ITK and is somehow relatex to our patched version of ITK filter UnaryFunctor.
It is the same bug we've got earlier in the Superimpose app:
http://hg.orfeo-toolbox.org/OTB/rev/901996766279
I'm currrently investigating the issue. I let you know.
1409563411 - grizonnetmI've got one suspect:
Commenting calls to MultiplyByScalarImageFilter in the OpticalCalibration app fix the issue
1409571931 - grizonnetmI've got a fix which consist in replac